Design of Blast-Resistant Buildings in Petrochemical Facilities

This updated edition provides general guidelines in the structural design of blast resistant petrochemical facilities. Informational coverage is provided for OSHA requirements, design objectives, siting considerations, and load determination with references mentioned for more detailed information. M...

Full description

Saved in:
Bibliographic Details
Corporate Author: Society of Civil Engineers. Task Committee on Blast Resistant Design
Format: Book
Language:English
Published: Reston, Virginia American Society of Civil Engineers 2010
Edition:SECOND EDITION
Subjects:
Online Access:Click Here to View Status and Holdings.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000nam#a2200000#i#4501
001 wils-453072
005 20191012143429
008 t 000 eng D
020 # # |a 9780784410882 
020 # # |a 0784410887 
040 # # |a DLC  |d UiTM  |e rda 
041 0 # |a eng 
090 0 0 |a TH4571  |b .D47 2010 
245 0 0 |a Design of Blast-Resistant Buildings in Petrochemical Facilities  |c Task Committee on Blast-Resistant Design 
250 # # |a SECOND EDITION 
264 # 1 |a Reston, Virginia  |b American Society of Civil Engineers  |c 2010 
264 # 4 |c ©2010 
300 # # |a x, 300 pages  |b illustrations  |c 22 cm 
336 # # |a text  |2 rdacontent 
337 # # |a unmediated  |2 rdamedia 
338 # # |a volume  |2 rdacarrier 
504 # # |a Includes bibliographical references (p. 287-296) and index 
520 # # |a This updated edition provides general guidelines in the structural design of blast resistant petrochemical facilities. Informational coverage is provided for OSHA requirements, design objectives, siting considerations, and load determination with references mentioned for more detailed information. More detailed coverage is provided for types of construction, dynamic material strengths, allowable response criteria, analysis methods, and design procedures. Typical details and ancillary considerations, such as doors and windows, are also included. A "how to" discussion on the upgrade of existing buildings is provided for older facilities which may not meet current needs. Three example calculations are included to illustrate design procedures. 
650 # 0 |a Petroleum refineries  |x Design and construction 
650 # 0 |a Petroleum refineries  |x Fires and fire prevention 
650 # 0 |a Explosions  |x Fires and fire prevention 
650 # 0 |a Buildings  |x Blast effects 
710 2 # |a Society of Civil Engineers.  |b Task Committee on Blast Resistant Design. 
856 4 0 |z Click Here to View Status and Holdings.  |u https://opac.uitm.edu.my/opac/detailsPage/detailsHome.jsp?tid=453072